Skip to content

Free guidance. No fees. No sales calls.

Answer

Do bifold doors let in draughts?

Short answer

Properly specified and fitted bifolds should not have persistent unwanted draughts. Their joints and
thresholdthreshold: A threshold is the bottom part of a door set that you cross when entering or leaving. It connects the door seals, drainage and floor levels. A low or visually flush threshold can make movement easier, but it still needs an appropriate weather detail and a properly planned external water route. More on threshold
need correct alignment and sealing, especially on exposed sites. Feeling cold near glass does not always mean air is leaking. Ask the installer to distinguish a draught from cool surface effects and inspect the complete installation rather than blaming all bifolds.

Planning this? Get a free, no-obligation installer recommendation

No — well-fitted bifolds should not leak cold air, but weak points exist

Modern
thermally brokenthermal break: A thermal break is a less conductive connection separating the inner and outer parts of a metal frame to reduce heat flow through it. It helps improve frame performance but does not determine the whole window result alone. Glass, spacers, geometry and the installation junction all remain part of the assessment. More on thermal break
bifold doors with multi-point compression seals should not feel draughty in normal weather. However, because a 4-panel bifold has more vertical meeting joints and a longer bottom track than a 2-pane slider, poor toe-and-heeling, an unrebated low
thresholdthreshold: A threshold is the bottom part of a door set that you cross when entering or leaving. It connects the door seals, drainage and floor levels. A low or visually flush threshold can make movement easier, but it still needs an appropriate weather detail and a properly planned external water route. More on threshold
on a windward elevation, or missed perimeter foam behind the frame trims will show up quickly as cold air movement.

Draught versus cold-glass downdraught

Before blaming a seal, test whether air is genuinely blowing through a joint or simply cooling against a large sheet of glass and sinking toward the floor. Holding a thin strip of tissue paper along the hinge joints,
thresholdthreshold: A threshold is the bottom part of a door set that you cross when entering or leaving. It connects the door seals, drainage and floor levels. A low or visually flush threshold can make movement easier, but it still needs an appropriate weather detail and a properly planned external water route. More on threshold
and wall perimeter on a breezy day shows immediately whether the gasket is leaking or whether the room simply needs better thermal glass or radiator placement.

Why low flush thresholds leak more on exposed walls

A weathered rebated
thresholdthreshold: A threshold is the bottom part of a door set that you cross when entering or leaving. It connects the door seals, drainage and floor levels. A low or visually flush threshold can make movement easier, but it still needs an appropriate weather detail and a properly planned external water route. More on threshold
closes the bottom of every panel against an upstand and gasket. A completely flush internal/external track relies on brush seals instead of a compression stop, which is why exposed or coastal elevations almost always stay warmer and drier with a weathered
thresholdthreshold: A threshold is the bottom part of a door set that you cross when entering or leaving. It connects the door seals, drainage and floor levels. A low or visually flush threshold can make movement easier, but it still needs an appropriate weather detail and a properly planned external water route. More on threshold
.

What to check

  • Record where and when the draught occurs
  • Check alignment and original seals with the installer
  • Keep drainage and planned ventilation unobstructed

Print this page to use the checklist on the day.

Questions people also ask

Should I add adhesive draught strips?
Ask the installer first. Extra strips may interfere with locking, drainage or the designed seals.
Is cold air beside the glass always a leak?
No. Cooling at the surface can move room air even when the joints are sealed.
Can a low threshold cause problems?
An unsuitable weather detail can. Check the exact
thresholdthreshold: A threshold is the bottom part of a door set that you cross when entering or leaving. It connects the door seals, drainage and floor levels. A low or visually flush threshold can make movement easier, but it still needs an appropriate weather detail and a properly planned external water route. More on threshold
specification and exposure rather than its height alone.

Last reviewed:

Answered by the Windows & Doors Answered team. How we write answers · Corrections policy

Ask a free question

Didn't find your answer? Ask the team. The team usually replies within one working day.

Free guidance. No fees. No sales calls.

We use your question only to write back with an answer. Privacy policy.