Skip to content

Free guidance. No fees. No sales calls.

Aluminium roof lantern bringing daylight into a modern kitchen extension

Product hub

Rooflights

Free guidance. No fees. No sales calls.

Short answer

Rooflights bring direct overhead daylight into flat-roof extensions, loft conversions and dark internal rooms without the raised ridge profile of a roof lantern. Available as fixed flat-glass units, electric opening vents, pitched roof windows and walk-on terrace glass, they require a slight drainage fall (typically 3 to 5 degrees), solar-control glazing and a laminated inner safety pane.

Planning this? Get a free, no-obligation installer recommendation

Key facts at a glance

Rooflights key facts
FactUK guide figure or ruleSource & checked
Typical price rangeTypical skylight supply-and-fit installation averages around £1,500 (flat roof skylight unit from £400, larger units £800 to £1,500+; Checkatrade skylight cost guide, last updated Sep 2026, excl. VAT; checked 25 Nov 2026).Checkatrade skylight installation cost guide (last updated Sep 2026, excl. VAT)Checked 25 November 2026
U-value rangeEngland Part L sets a limiting whole-unit
U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
of 2.2 W/m²K for replacement roof windows and rooflights (tighter notional targets for new extensions and homes); Scotland Section 6 sets strict fabric
U-valuesU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
. Confirm the horizontal whole-unit Uw value.
GOV.UK Approved Document L & Scottish Technical HandbookChecked 24 November 2026
LifespanDepends on stepped-glass edge UV protection, upstand drainage pitch (avoiding standing water), frame
thermal breakthermal break: A thermal break is a less conductive connection separating the inner and outer parts of a metal frame to reduce heat flow through it. It helps improve frame performance but does not determine the whole window result alone. Glass, spacers, geometry and the installation junction all remain part of the assessment. More on thermal break
and roof membrane flashing.
Awaiting maker data
MaintenanceRinse glass periodically (a 3–5 degree pitch plus self-cleaning coating helps rain shed dirt); keep flat-roof outlets clear and check perimeter flashing and electric actuators annually.Windows & Doors Answered trade teamChecked 24 November 2026
Security standardsChoose laminated inner safety/security glass, concealed fixings and non-fragile certification; check
PAS 24PAS 24: PAS 24 is a security test specification for complete windows and external door sets. It examines resistance to defined attack methods rather than promising that a product cannot be broken into. Evidence should relate to the actual system, configuration and hardware, not merely a lock or a broad product range. More on PAS 24
availability for easily accessible flat roofs where Approved Document Q applies.
GOV.UK Approved Document Q & Approved Document KChecked 24 November 2026
Lead timeStandard stock flat-glass sizes ship faster than bespoke multi-pane modular rooflights, electric openers or structural walk-on units.Awaiting maker data
This is general information, not planning, building-regulations or legal advice. Rules depend on the property, the work and the nation you live in. Confirm your own project with your local council or building control body before ordering.

What are rooflights?

A rooflight is a glazed roof aperture designed to channel overhead daylight straight down into a room below. On flat-roof extensions, modern frameless-look flat glass rooflights sit neatly over an insulated weathered upstand so from inside you see almost uninterrupted sky with no visible framing; on pitched roofs, conservation or centre-pivot roof windows integrate into tiles or slates with dedicated flashing kits.
Because flat rooflights sit nearly horizontal, water runoff, UV edge-seal protection, solar heat gain and rain noise demand far more careful specification than an ordinary vertical window.

Types and opening styles of rooflights

Choose the rooflight format that matches your roof construction and how the space is used:
  • Fixed flat-glass rooflights: Minimalist frameless-look glass units for flat roofs — lowest cost, cleanest internal
    sightlinesightline: A sightline is the visible width of frame you see when you look at a window or door. Slimmer sightlines mean more glass and less frame. Makers sometimes measure it differently, so compare drawings of the exact products, especially where fixed and opening panes sit side by side. More on sightline
    and fewest seals.
  • Electric or manual opening flat rooflights: Hinged units with concealed actuators and optional rain sensors for hot kitchens or windowless bathrooms.
  • Modular multi-pane / ridge rooflights: Long strips of structural glass joined with silicone joints spanning wide extensions.
  • Walk-on terrace rooflights: Heavy multi-layer structural
    laminated glasslaminated glass: Laminated glass has glass layers bonded around an interlayer that can hold broken pieces together. Depending on its specification, it may serve safety, security or acoustic purposes. Those functions are not automatic: the glass build-up, supporting frame and tested application decide what protection the complete assembly can provide. More on laminated glass
    with optional anti-slip frit for roof terraces or basement lightwells.
  • Pitched roof windows and conservation rooflights: Flush-fitting slate or tile roof windows for loft conversions and barn roofs.
Never buy a standard flat rooflight for a roof terrace where anyone might step on it — walk-on glass is a completely different structural engineering specification.

Pros and cons of rooflights

Where they work well

  • Low, unobtrusive external profile that clears upstairs windowsills and appeals to planners in sensitive areas.
  • Edge-to-edge frameless internal appearance floods rooms with crisp daylight without heavy rafters.
  • Available in triple glazing, solar-control glass, acoustic
    laminated glasslaminated glass: Laminated glass has glass layers bonded around an interlayer that can hold broken pieces together. Depending on its specification, it may serve safety, security or acoustic purposes. Those functions are not automatic: the glass build-up, supporting frame and tested application decide what protection the complete assembly can provide. More on laminated glass
    and electric venting.
  • Generally simpler to clean and lower in visual bulk than a tall pitched roof lantern.

Where to be cautious

  • Requires a built-in 3- to 5-degree drainage pitch on the upstand to prevent standing rainwater and dirty mineral rings.
  • Very large single-pane flat rooflights become extremely heavy and often need crane lifting onto the roof.
  • Overhead glass transmits more rain noise and summer solar heat than a solid insulated roof unless specified carefully.
  • Does not add the vaulted ceiling height of a pitched roof lantern.

How much do rooflights cost in the UK?

UK price ranges for rooflights vary because pricing spans from compact stock fixed flat-glass units to custom electric-opening, triple-glazed or structural walk-on systems with crane delivery.

What drives the price up or down

  • Stock vs bespoke dimensions: Standard stock sizes save significantly over custom-cut units.
  • Fixed vs electric opening: Concealed motors, rain sensors, wall switches and electrical wiring add substantially to unit cost.
  • Double vs triple glazing and walk-on glass: Triple glazing and structural walk-on laminated builds carry major glass and lifting uplifts.
  • Upstand and roof membrane: Building, insulating and waterproofing a pitched 150 mm upstand is usually carried out by your builder/roofer.

Worked cost example

Flat-rooflight installed prices vary by roof size and crane access. Price the opening by separating: (1) builder's structural roof trimmers and pitched 150 mm insulated upstand, (2) rooflight unit with solar-control + laminated inner glass, (3) roof lifting/fitting, and (4) electrical connection if opening.

Budgeting and quote tools

Thermal performance and Part L / Scotland rules

Check that the quoted
U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
is the whole-unit Uw value calculated in the horizontal (installed) orientation, not a vertical glass Ug figure — horizontal air cavities convect more heat than vertical cavities, making horizontal
U-valuesU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
higher for the same glass. Insulate the timber upstand thoroughly so cold bridges do not cause winter condensation around the ceiling
revealreveal: A reveal is the exposed side, top or bottom surface of a wall opening around a window or door. Its depth affects how the frame sits within the wall and how the junction is insulated and finished. Internal and external reveals may need different sealing and making-good details. More on reveal
.

Thermal and glazing tools

Security: PAS 24 and Secured by Design

On accessible single-storey roofs, choose rooflights with concealed perimeter fixings, laminated inner safety/security glass and
PAS 24PAS 24: PAS 24 is a security test specification for complete windows and external door sets. It examines resistance to defined attack methods rather than promising that a product cannot be broken into. Evidence should relate to the actual system, configuration and hardware, not merely a lock or a broad product range. More on PAS 24
testing where Approved Document Q applies.

Noise and acoustic performance

Rain impact on a nearly horizontal pane is louder than on a vertical window. Specifying a laminated inner pane (and acoustic
laminated glasslaminated glass: Laminated glass has glass layers bonded around an interlayer that can hold broken pieces together. Depending on its specification, it may serve safety, security or acoustic purposes. Those functions are not automatic: the glass build-up, supporting frame and tested application decide what protection the complete assembly can provide. More on laminated glass
over bedrooms or quiet living spaces) cuts rain-drumming noise noticeably.

Lifespan and maintenance

Flat-rooflight service life depends on specification, exposure and written warranties. The single biggest factor in longevity is drainage pitch: a 3- to 5-degree fall stops puddles sitting permanently on silicone joints and stepped glass edges. Rinse glass periodically and keep flat-roof gutters clear.

Colours and finishes

Most flat-glass rooflights feature a slim perimeter ceramic frit border in Jet Black (
RALRAL: RAL is a colour reference system used to specify finishes, including many coated aluminium windows and doors. A reference identifies a colour target, not a guarantee that different materials or finishes will look identical. Surface texture, gloss, lighting and the coating process can alter how the chosen shade appears. More on RAL
9005) or Anthracite Grey (
RALRAL: RAL is a colour reference system used to specify finishes, including many coated aluminium windows and doors. A reference identifies a colour target, not a guarantee that different materials or finishes will look identical. Surface texture, gloss, lighting and the coating process can alter how the chosen shade appears. More on RAL
7016) externally and a clean white or dark-framed upstand internally.

Explore colours and finishes

Systems and brands

Well-known UK rooflight makers include Velux (pitched and flat-roof ranges), Roofmaker, Glazing Vision, Sunsquare, Brett Martin and Duplus. Compare horizontal whole-unit
U-valuesU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
, non-fragility certification, stepped-glass UV edge protection and written warranty terms.

Planning permission and building control

Flat rooflights on rear single-storey extensions are commonly
permitted developmentpermitted development: Permitted development is a system of rights allowing certain work without a separate planning permission application, subject to conditions and limits. It does not remove building regulations or listed-building obligations. Rights differ between England and Scotland and can be restricted, so check the specific property and proposed work before relying on them. More on permitted development
in England when within height limits, and low-profile flush conservation rooflights are often preferred by planners on pitched roofs in conservation areas and National Parks. Always verify structural roof alterations with
building controlbuilding control: Building control is the process of checking relevant building work against applicable building regulations. It is separate from planning permission. The route and required paperwork depend on the work and where the building is located; Scotland uses a building standards system with warrants where required and completion procedures through the verifier. More on building control
or a Scottish building warrant.

Planning and rules tools

How rooflights are surveyed and fitted

Confirm whether the manufacturer supplies a prefabricated insulated kerb or requires your builder to form a pitched, weathered timber upstand to exact external dimensions (including membrane thickness). Check unit weight early — large flat rooflights frequently need a crane or hoist.

Survey and fitting guides

What a good quote must include

Verify these rooflight essentials on every quote before ordering:

Rooflights quote checklist

  • Exact external weathered upstand size, required drainage pitch (3–5 degrees) and minimum 150 mm upstand height
  • Horizontal whole-unit
    U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
    (Uw), solar-control
    g-valueg-value: A g-value describes the proportion of solar energy that passes through glazing into a room. A lower value means less solar heat enters, but it does not directly tell you how much visible light passes through. Consider it alongside light transmission, shading and the direction the glazing faces. More on g-value
    and laminated inner safety pane
  • Fixed vs electric opening spec (including rain sensor and transformer) or structural walk-on certification if applicable
  • Delivery weight, roof-lifting/crane responsibility and written sealed-unit/frame warranties

Print this page to use the checklist on the day.

Red flags to watch out for

Avoid these common rooflight pitfalls:
  • Installing a flat-glass rooflight dead level (0 degrees), causing permanent rainwater ponding and premature edge-seal failure.
  • Accepting a vertical centre-pane Ug figure instead of the installed horizontal whole-unit Uw value.
  • Using standard non-walk-on glass on a roof terrace or balcony.
  • Forgetting to check delivery weight before the crane leaves site on a new extension.

Questions to ask an installer

Ask your rooflight supplier and builder these five questions:
  • What is the whole-unit
    U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
    calculated in the horizontal installed orientation?
  • What exact minimum drainage pitch and weathered external upstand dimensions do you require?
  • Is the inner pane laminated for overhead safety and rain-noise reduction, and what is the solar-control
    g-valueg-value: A g-value describes the proportion of solar energy that passes through glazing into a room. A lower value means less solar heat enters, but it does not directly tell you how much visible light passes through. Consider it alongside light transmission, shading and the direction the glazing faces. More on g-value
    ?
  • How much does the unit weigh, and who is responsible for lifting it onto the roof?
  • What warranty covers edge-seal misting and any electric opening motors?

Choosing an installer

How it is surveyed and fitted: step by step

  1. Choose fixed, opening or walk-on specification

    Match rooflight type to ventilation needs, ceiling access and whether the roof is trafficable.
  2. Specify solar control, laminated inner pane and pitch

    Confirm horizontal Uw value,
    g-valueg-value: A g-value describes the proportion of solar energy that passes through glazing into a room. A lower value means less solar heat enters, but it does not directly tell you how much visible light passes through. Consider it alongside light transmission, shading and the direction the glazing faces. More on g-value
    , laminated safety glass and a 3–5 degree upstand fall.
  3. Build and weatherproof the insulated upstand

    Have your builder form a level-topped (or 3–5° pitched) 150 mm insulated upstand dressed cleanly with roof membrane.
  4. Check finished external upstand sizes before manufacture

    Measure actual weathered upstand dimensions and confirm lifting access onto the roof.
  5. Bed unit onto continuous weather seals

    Lift the rooflight safely onto the kerb, fix mechanically through approved perimeter brackets and wire any electric opener.
  6. Water-test flashing and finish internal lightwell

    Confirm clean water runoff off the glass, check electric rain sensors if fitted and keep all warranty documents.

Compare rooflights against the alternatives

Glazing options compared for rooflights: double, triple, solar-control and self-cleaning
ComparedDouble glazingTriple glazingSolar control glassSelf-cleaning glass
Look and sightlinesClear view; tint and reflections depend on glass and coatings rather than pane count alone.Extra glass may affect reflections and light transmission; examine the exact unit.Dual-function low-E and solar-control coated glass such as Pilkington Suncool 70/35 (available in 6, 8 and 10 mm toughened) reflects summer solar heat while keeping a neutral appearance.Dual-action on-line pyrolytic coating on surface #1 (for example Pilkington Activ / Activ Suncool) uses daylight photo-catalysis to break down organic dirt and hydrophilic sheeting so rain rinses it away.
Maximum sizesMaximum widths and heights for Double glazing depend on wind load and glass weight — confirm against the maker's size chart.Maximum widths and heights for Triple glazing depend on wind load and glass weight — confirm against the maker's size chart.Maximum widths and heights for Solar control glass depend on wind load and glass weight — confirm against the maker's size chart.Maximum widths and heights for Self-cleaning glass depend on wind load and glass weight — confirm against the maker's size chart.
Thermal performanceManufactured to BS EN 1279-1/-5 insulating glass unit standards; low-E double glazing such as Pilkington K Glass S supports England's Approved Document L Table 4.2 replacement limit of 1.4 W/m²K (or
WERWindow Energy Rating: A Window Energy Rating is a label assessing a window as a complete product, taking account of heat loss, solar gain and air leakage. It is not the same measurement as a glass U-value. Compare labels for the proposed window configuration and consider the room orientation alongside the rating. More on Window Energy Rating
Band B).
Three-pane BS EN 1279 units with two low-E cavities enable whole-window Uw down to 0.71 to 0.88 W/m²K across high-performance UK/European window systems (for example Senior PURe 0.75 W/m²K, VEKA M70 0.75 W/m²K, VELFAC 200 triple 0.80 to 1.00 W/m²K).Pilkington Suncool 70/35 publishes a centre-pane Ug value of 1.0 W/m²K while cutting solar heat gain on south, east and west elevations.Dual-coated Pilkington Activ Suncool combines surface #1 self-cleaning with a surface #2 solar-control
low-E coatinglow-E coating: A low-E coating is a thin, low-emissivity layer on glass that reduces the transfer of heat by radiation. It helps insulating glazing retain warmth. It is not automatically solar-control glass, and the complete specification still needs to address light, summer heat, safety and the performance of the sealed unit. More on low-E coating
inside BS EN 1279 sealed units.
Security standardImpact safety in critical locations (below 800 mm in windows or 1,500 mm in doors/side panels) requires BS EN 12600 safety glass on both panes under Approved Document K.Extra panes alone do not establish security or impact safety; critical locations still require BS EN 12600 safety glass or BS EN 356 laminated security glazing.Pilkington Suncool 70/35 is supplied in toughened form for Approved Document K critical locations; specify laminated BS EN 356 glass if manual-attack resistance is required.Self-cleaning coating is unrelated to impact safety; specify BS EN 12150 toughening or BS EN 14449 laminating for Approved Document K zones.
Ease of useUsually lighter than an otherwise comparable triple unit; frame design still controls operation.More glass adds weight; hinges and frames must be designed for the unit.Passive solar-gain reduction without daily adjustment, but it is fixed year round.Coating uses daylight and water; sheltered areas may still need rinsing and manual cleaning.
MaintenanceClean accessible faces; failed sealed units need assessment and replacement.Similar surface cleaning, but replacement units require suitable handling and compatible frames.Care depends on the coating surface; follow the supplier's instructions.Only use approved cleaning products and compatible sealants; it is not maintenance-free.
Expected lifespanService life for Double glazing depends on exposure, specification and care — ask for the written frame, finish and hardware warranties.Service life for Triple glazing depends on exposure, specification and care — ask for the written frame, finish and hardware warranties.Service life for Solar control glass depends on exposure, specification and care — ask for the written frame, finish and hardware warranties.Service life for Self-cleaning glass depends on exposure, specification and care — ask for the written frame, finish and hardware warranties.
Typical price bandDouble-glazed windows average around £1,000 per window incl. VAT (Checkatrade triple-glazing guide, last updated Oct 2026), with basic uPVC
casementscasement: A casement is a hinged window opening, usually attached at the side or top of its frame. It opens rather than sliding vertically like a traditional sliding sash. The hinge position and opening direction affect ventilation, cleaning, clear passage and conflicts with paths, taps, curtains or furniture. More on casement
£350 to £520 and a 12-window 3-bed house averaging £7,500 (Checkatrade new windows guide, last updated Jul 2026, excl. VAT; checked 25 Nov 2026) (typical published UK range, supplied and fitted).
Triple-glazed windows average around £1,200 per window incl. VAT, or ~£9,600 for an 8-window semi-detached house (Checkatrade, last updated Oct 2026); Homebuilding & Renovating (published 2 Jun 2024) advises budgeting at least a 20% uplift over double glazing (checked 25 Nov 2026) (typical published UK range, supplied and fitted).Installed cost for Solar control glass varies with size, glazing and site access — compare two or three itemised written quotes.Installed cost for Self-cleaning glass varies with size, glazing and site access — compare two or three itemised written quotes.
Best forStraightforward upgrades where the whole window meets the project's thermal requirements.Low-energy projects where a specified improvement in whole-window performance is worthwhile.Sun-exposed glazing where an overheating assessment identifies excessive solar gain.Exposed glass that receives daylight and rain but is awkward to clean safely.
Watch-outsCompare whole-window performance; a glass-only figure leaves out the frame and edges.Not automatically quieter or better value; check acoustics, solar gain and actual performance.Can reduce useful winter sun and daylight; it is not a replacement for ventilation or shading design.Deep overhangs, bird fouling and stubborn deposits can limit its benefit.

Figures from published manufacturer data, building regulations and UK cost guides. Your price will depend on your project.

Prices are published guide figures from the sources listed, not our own quotes. Installed prices vary by UK region, access, glazing specification and making good.


The team's verdict

Flat-glass rooflights are the cleanest architectural choice when you want abundant overhead daylight with minimal visual clutter from the room below and a low external silhouette that clears first-floor windowsills or conservation height limits. Just never install a flat rooflight dead level — build a gentle 3- to 5-degree fall into the upstand so rainwater sheds cleanly instead of ponding and leaving mineral rings across the glass.

Everything we've answered about rooflights

Every comparison, answer, buying guide, fitting step, planning rule, system review, colour and glossary entry on this site covering rooflights (49 pages).

Questions people also ask

What is the difference between a rooflight and a roof lantern?
A rooflight sits low and flat (or flush with a pitched roof), while a roof lantern rises as a pitched glazed pyramid or ridge above a flat roof.
Why does a flat rooflight need a slight pitch?
Building a 3- to 5-degree slope into the upstand lets rainwater drain off instead of pooling on the glass, preventing dirty mineral rings and extending edge-seal life.
Do flat rooflights overheat a room?
Large south- or west-facing rooflights can cause summer overheating unless you specify a solar-control outer coating and adequate room ventilation.
Are flat rooflights noisy in heavy rain?
Specifying a laminated inner pane (or acoustic
laminated glasslaminated glass: Laminated glass has glass layers bonded around an interlayer that can hold broken pieces together. Depending on its specification, it may serve safety, security or acoustic purposes. Those functions are not automatic: the glass build-up, supporting frame and tested application decide what protection the complete assembly can provide. More on laminated glass
) noticeably softens rain-drumming noise compared with plain toughened double glazing.
Can you open a flat rooflight for ventilation?
Yes — electric hinged rooflights with concealed actuators and automatic rain sensors are widely available, though they cost more than fixed units.
Can I walk on a flat rooflight?
Only if it is specifically engineered and certified as a walk-on structural glass unit with appropriate multi-layer
laminated glasslaminated glass: Laminated glass has glass layers bonded around an interlayer that can hold broken pieces together. Depending on its specification, it may serve safety, security or acoustic purposes. Those functions are not automatic: the glass build-up, supporting frame and tested application decide what protection the complete assembly can provide. More on laminated glass
and anti-slip treatment.
How thick should a flat rooflight upstand insulation be?
Wrap the timber upstand externally with rigid insulation (typically 50 mm or as specified by your
building controlbuilding control: Building control is the process of checking relevant building work against applicable building regulations. It is separate from planning permission. The route and required paperwork depend on the work and where the building is located; Scotland uses a building standards system with warrants where required and completion procedures through the verifier. More on building control
/designer) to avoid cold bridging and winter condensation.
Do rooflights need planning permission?
Whether rooflights require planning permission depends on projection height, roof slope, conservation-area or listed status, and local planning conditions. Verify the rules with your local planning authority and the Planning Portal before work begins.
Is triple glazing worth it on a flat rooflight?
Triple glazing lowers horizontal heat loss further and helps meet strict new-build fabric targets, though check the extra weight and lifting requirements.
Do rooflights have self-cleaning glass?
Self-cleaning coatings can be added, though they rely on at least a 3–5 degree pitch (and work better on steeper pitches) so rainwater can sheet away broken-down dirt.
Are rooflights secure against burglars?
Choose units with laminated inner glass, concealed fixings and
PAS 24PAS 24: PAS 24 is a security test specification for complete windows and external door sets. It examines resistance to defined attack methods rather than promising that a product cannot be broken into. Evidence should relate to the actual system, configuration and hardware, not merely a lock or a broad product range. More on PAS 24
testing where the flat roof is easily accessible.
Why is a rooflight U-value higher than a vertical window with the same glass?
Warm air rises inside a horizontal glass cavity and transfers heat faster than in a vertical cavity, so always check the horizontal installed Uw value.
Can I fit blinds to a flat rooflight?
Yes — electric pleated or blackout blinds can be fitted neatly inside the plaster lightwell below the glass.
What is a conservation rooflight?
A slimline, low-profile pitched roof window with a central vertical glazing bar designed to sit flush with natural slate or clay tiles on period and heritage roofs.
How long do flat rooflights take to deliver?
Lead times are confirmed on the itemised written quote — standard stock fixed sizes are usually quick, while bespoke sizes, electric openers and walk-on units take longer.

Sources and editorial review

Who wrote this guide

Answered by the Windows & Doors Answered team. Last reviewed: .

Home Glazing Ltd, which runs this site, also owns Windows in the Lakes and Windows in the Dales. Where your postcode is in their area, one of them may be one of the installers we introduce, and only if you tick the box. Every guide follows the same sourcing rules whoever installs, figures are dated and sourced, and no installer pays to be mentioned.

Read how we write and check answers or report a correction.

Ask a free question

Didn't find your answer? Ask the team. The team usually replies within one working day.

Free guidance. No fees. No sales calls.

We use your question only to write back with an answer. Privacy policy.

Ask a follow-up about this page