How much glass can I have in an extension under building regulations?

Short answer

There is no simple maximum that applies to every extension. In England, Approved Document L sets a reference amount of glazing for extensions, and larger amounts usually need a calculation showing the extension performs no worse overall. Scotland uses its own
building standardsbuilding control: Building control is the process of checking relevant building work against applicable building regulations. It is separate from planning permission. The route and required paperwork depend on the work and where the building is located; Scotland uses a building standards system with warrants where required and completion procedures through the verifier. More on building control
. Your designer or
building controlbuilding control: Building control is the process of checking relevant building work against applicable building regulations. It is separate from planning permission. The route and required paperwork depend on the work and where the building is located; Scotland uses a building standards system with warrants where required and completion procedures through the verifier. More on building control
body should confirm the allowance for your project.

Planning this? Get a free, no-obligation installer recommendation

This is general information, not planning, building-regulations or legal advice. Rules depend on the property, the work and the nation you live in. Confirm your own project with your local council or building control body before ordering.

The 25% reference area in England

Under England's Approved Document L, Volume 1 (2021 edition incorporating 2023 amendments, Section 10, paragraph 10.7(d); checked 26 November 2026), the total area of windows, roof windows, rooflights and doors in an extension should not exceed 25% of the extension's floor area plus the total area of any windows and doors that no longer exist or are no longer exposed due to the extension. Where a proposed design exceeds that reference area, paragraphs 10.9 and 10.10 set out alternative compliance routes using an area-weighted
U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
or SAP calculation, which your energy assessor or designer submits to
building controlbuilding control: Building control is the process of checking relevant building work against applicable building regulations. It is separate from planning permission. The route and required paperwork depend on the work and where the building is located; Scotland uses a building standards system with warrants where required and completion procedures through the verifier. More on building control
for approval.

Why wide doors and rooflights trigger a calculation early

Combining wide patio doors with a roof lantern or flat rooflights can push the total glazed area above the 25% reference
thresholdthreshold: A threshold is the bottom part of a door set that you cross when entering or leaving. It connects the door seals, drainage and floor levels. A low or visually flush threshold can make movement easier, but it still needs an appropriate weather detail and a properly planned external water route. More on threshold
even on a modest rear extension. Ask your architect, designer or energy assessor to check the glazing area and run any required compensating calculation before drawings are finalised or frames are ordered.

Scotland and summer overheating

Scotland assesses extension glazing under the Domestic Technical Handbook through the building warrant process using its own elemental and whole-building heat-loss checks rather than England's Part L table. On either side of the border, check summer overheating early on south- and west-facing glass boxes — passing winter heat-loss rules does not stop a room baking in July.

What to check

  • Ask the designer to check the glazing area early
  • Expect a calculation if the glazing exceeds the reference amount
  • Consider summer overheating as well as winter heat loss

Print this page to use the checklist on the day.

Official information

Questions people also ask

Does a glass box extension need approval?
Yes, most extensions need
building controlbuilding control: Building control is the process of checking relevant building work against applicable building regulations. It is separate from planning permission. The route and required paperwork depend on the work and where the building is located; Scotland uses a building standards system with warrants where required and completion procedures through the verifier. More on building control
approval in England or a building warrant in Scotland, regardless of how much glass they have.
Can better glass let me have more of it?
Often it helps in a compensating calculation, but the overall result depends on the whole extension and the existing house.
Who does the calculation?
Usually an energy assessor or the designer, submitted to
building controlbuilding control: Building control is the process of checking relevant building work against applicable building regulations. It is separate from planning permission. The route and required paperwork depend on the work and where the building is located; Scotland uses a building standards system with warrants where required and completion procedures through the verifier. More on building control
. Ask who is responsible before the drawings are finished.

Last reviewed:

Answered by the Windows & Doors Answered team. How we write answers · Corrections policy