What's the difference between installation in a timber frame vs masonry build?

Short answer

In masonry, windows are usually fixed into the masonry opening and sealed to the cavity. In timber frame, they are often fixed to the frame, with allowance for the timber shrinking and settling while the outer skin does not. The fixing position, membranes and movement gaps differ, so agree the detail with the frame designer.

Planning this? Get a free, no-obligation installer recommendation

Differential shrinkage is the key difference between timber frame and masonry

In a masonry cavity wall, windows are fixed directly into blockwork or brick
revealsreveal: A reveal is the exposed side, top or bottom surface of a wall opening around a window or door. Its depth affects how the frame sits within the wall and how the junction is insulated and finished. Internal and external reveals may need different sealing and making-good details. More on reveal
via straps or masonry screws once openings are formed; in a timber-frame build, windows are typically fixed straight to the structural timber stud opening before the outer brick or cladding skin goes up, leaving deliberate compressible movement gaps at heads and
cillscill: A cill is the lower projecting section beneath a window or door frame that helps shed rainwater away from the wall. It is also spelt sill. Its projection, joints and connection to the frame need to suit the wall construction, so water does not collect or run into vulnerable junctions. More on cill
so the timber frame can settle vertically without resting on the rigid outer brickwork.

How airtightness tapes and breather membranes differ

Timber-frame walls rely on an internal vapour control / airtightness layer and an external breather membrane, both of which must lap neatly onto the window perimeter with specialist tapes. If the window installer relies solely on standard expanding foam and external silicone without taping to the membranes, the airtightness test can fail and wind-driven rain can track behind the cladding.

Sequence the window survey with the timber-frame erector

On timber-frame self-builds, frames are often ordered from verified factory stud dimensions so the shell goes weather-tight immediately after erection — confirm in writing who guarantees aperture accuracy and who supplies the
cillcill: A cill is the lower projecting section beneath a window or door frame that helps shed rainwater away from the wall. It is also spelt sill. Its projection, joints and connection to the frame need to suit the wall construction, so water does not collect or run into vulnerable junctions. More on cill
movement-joint trays.
Timber-frame vs masonry window installation details
DetailTimber-frame buildMasonry cavity build
Primary fixingFixed to structural timber studs /
revealreveal: A reveal is the exposed side, top or bottom surface of a wall opening around a window or door. Its depth affects how the frame sits within the wall and how the junction is insulated and finished. Internal and external reveals may need different sealing and making-good details. More on reveal
liner
Fixed to inner blockwork or brick
revealreveal: A reveal is the exposed side, top or bottom surface of a wall opening around a window or door. Its depth affects how the frame sits within the wall and how the junction is insulated and finished. Internal and external reveals may need different sealing and making-good details. More on reveal
with straps/anchors
Movement allowanceCompressible head/
cillcill: A cill is the lower projecting section beneath a window or door frame that helps shed rainwater away from the wall. It is also spelt sill. Its projection, joints and connection to the frame need to suit the wall construction, so water does not collect or run into vulnerable junctions. More on cill
movement gap to allow frame settlement
Standard perimeter expansion joint (typically 5–10 mm)
Weather & air sealExternal breather membrane + internal airtightness tape lapped to frameInsulated cavity closer, low-expansion foam and external mastic/compriband
Timing on siteOften installed before outer brick/cladding to weather-tight the shellInstalled after masonry openings and
lintelslintel: A lintel is a structural member above an opening that carries loads from the wall or construction above. Its material and design depend on the building. A window or door frame is not a substitute for that support, and widening an opening requires assessment of the structure and its movement. More on lintel
are built and cured

What to check

  • Confirm the fixing position and fixings for the wall type
  • Agree movement gaps with the frame designer
  • Assign responsibility for membranes and airtight tapes

Print this page to use the checklist on the day.

Questions people also ask

Can any window be fitted into timber frame?
Most can, with the right fixings and details. Ask the window supplier for their timber frame detail.
Who is responsible for the movement gap?
Agree it in writing between the designer, frame supplier and window installer.
Should windows go in before the outer skin?
In some timber frame builds they do. Follow the agreed sequence for your wall design.

Last reviewed:

Answered by the Windows & Doors Answered team. How we write answers · Corrections policy