Skip to content

Free guidance. No fees. No sales calls.

White sash windows and a natural timber casement in a British red-brick home

Guide

Thermal performance and U-values for specifiers

Free guidance. No fees. No sales calls.

Short answer

Specify whole-window and whole-door
U-valuesU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
for the actual sizes, glass and opening arrangements, not glass-only brochure figures. Coordinate them with the applicable regulations and whole-building energy model. Distinguish regulatory limits from notional targets and product evidence. Review substitutions before ordering, then retain documents showing that the installed glazing matches the approved thermal specification.

Planning this? Get a free, no-obligation installer recommendation

This is general information, not planning, building-regulations or legal advice. Rules depend on the property, the work and the nation you live in. Confirm your own project with your local council or building control body before ordering.
The energy-rating answer explains a label; this guide coordinates thermal evidence, specification and substitutions.
U-valuesU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
do not describe ventilation, overheating or installation airtightness on their own. The published regulatory context below is reused from the maintained dataset, while project requirements and the applicable edition must be confirmed by the designer and relevant authority.

1. Define the calculation and project route

Establish nation, building type, new work or replacement, and the applicable approval and energy-calculation approach. Ask the assessor to state the glazing assumptions and identify which values are limits, design targets or calculation inputs. A notional reference value is not automatically a universal individual-product requirement. Record the project-specific criteria before suppliers propose a thermal specification.

2. Request comparable whole-product evidence

Ask for values covering the configured frame,
sashsash: A sash is the framed part of a window that holds the glass; it often describes the moving part. In a sliding sash window, glazed sashes move vertically. The word alone does not identify the material, balance mechanism or cleaning action, so ask what the complete window description actually means. More on sash
, glass, spacer and size, with the method and reference conditions identified. Distinguish whole-window, whole-door and centre-pane values. Check whether the evidence represents the actual opening arrangement or a standard reference sample. Product size and frame-to-glass proportions can change the result, so do not carry a best-case brochure value into every schedule line.

Before moving on

  • Limits and design targets are distinguished
  • Evidence covers the whole configured opening
  • Size and reference conditions are understood

Print this page to use the checklist on the day.

3. Coordinate interfaces and summer performance

Review frame position, insulated
revealsreveal: A reveal is the exposed side, top or bottom surface of a wall opening around a window or door. Its depth affects how the frame sits within the wall and how the junction is insulated and finished. Internal and external reveals may need different sealing and making-good details. More on reveal
, support, perimeter seals and air-barrier continuity with the wall design. Avoid treating a good product
U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
as proof of a good installed junction. Coordinate glass solar properties, orientation, shading and ventilation with summer comfort and the energy model. Increased glazing or a changed opening action can affect both thermal calculations and other performance requirements.

4. Control changes and completion evidence

Require proposed substitutions to include revised whole-product figures and the relevant glass properties. Have the assessor or designer review the effect before fabrication approval. Retain calculation revisions, configured product evidence, installed schedule and interface records. At completion, reconcile what was fitted with the approved assumptions and record any remaining discrepancy rather than handing over an unrelated generic technical brochure.

Published figures and their limits

Published regulatory window context

Must meet building regulations. England, replacement windows: maximum
U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
1.4 W/m²K or
Window Energy RatingWindow Energy Rating: A Window Energy Rating is a label assessing a window as a complete product, taking account of heat loss, solar gain and air leakage. It is not the same measurement as a glass U-value. Compare labels for the proposed window configuration and consider the room orientation alongside the rating. More on Window Energy Rating
band B. England, new homes: limiting
U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
1.6 W/m²K (notional 1.2). Scotland: maximum 1.4 W/m²K. Check the whole-window
U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
of the exact product.

Sources — checked 2026-11-23

Published regulatory glazed-door context

Must meet building regulations. England, replacement doors over 60% glazed: maximum 1.4 W/m²K or
DSERDSER: DSER means Door Set Energy Rating. It assesses an external door set as a complete assembly rather than judging the door glass on its own. The rating takes account of energy performance, including heat loss and air leakage. Ask whether the label covers the exact leaf, frame and glazing proposed. More on DSER
band C. England, new homes: limiting 1.6 W/m²K (notional 1.2). Scotland: maximum 1.4 W/m²K. Check the whole-door
U-valueU-value: A U-value describes how readily heat passes through a building element. A lower value means less heat loss through that element. For windows and doors, distinguish the complete assembly from the glass alone: a good glass figure does not establish the performance of the frame, edges and finished product. More on U-value
of the exact product.

Sources — checked 2026-11-23

Your project checklist

  • Confirm applicable regulations edition
  • Align the schedule with energy assumptions
  • Check whole-product values
  • Coordinate junctions and airtightness
  • Review solar properties and ventilation
  • Retain substitution and completion records

Print this page to use the checklist on the day.

What to do next

Create an evidence column for every scheduled opening and send it to the energy assessor with the configured product data. Resolve gaps before the order is approved. Carry the accepted values and interface details into the installation and completion records.

Relevant answers and comparisons

Useful tools

Official information

Questions people also ask

Can I specify only the glass U-value?
Not as a substitute for whole-window or whole-door performance. The frame, spacer, size and opening arrangement contribute to the complete result.
Is the notional value the same as the limiting value?
No. They serve different roles in the regulatory calculation. Confirm the project requirements with the designer and authority.
Does a better U-value remove overheating risk?
No. Solar gain, glazing area, shading, orientation and ventilation need separate assessment alongside winter heat loss.

Last reviewed:

Answered by the Windows & Doors Answered team. How we write answers · Corrections policy

Ask a free question

Didn't find your answer? Ask the team. The team usually replies within one working day.

Free guidance. No fees. No sales calls.

We use your question only to write back with an answer. Privacy policy.

Ask a follow-up about this page